Configure an SPBM Layer 2 Switched UNI on an MLT
Before you begin
You must configure the required SPBM and IS-IS infrastructure.
About this task
To configure a Switched UNI on an MLT, you must create a Switched UNI I-SID, and map an MLT to the Switched UNI I-SID.

Note
When you configure Switched UNI, Spanning tree is disabled on all Switched UNI ports.
Procedure
Example
Switch:1>enable Switch:1#configure terminal Switch:1(config)#mlt 10 Switch:1(config)#interface mlt 10 Switch:1(config-mlt)#flex-uni enable Switch:1(config-mlt)#i-sid 100 Switch:1(elan:100)#c-vid 20 mlt 10 Switch:1(elan:100)#untagged-traffic mlt 10 bpdu enable
Switch:1(elan:100)#show mlt i-sid
================================================================================
MLT Isid Info
================================================================================
ISID ISID ISID
MLTID IFINDEX ID VLANID C-VID TYPE ORIGIN NAME BPDU
--------------------------------------------------------------------------------
10 6153 100 N/A 20 ELAN C --- - --- - EXTR
11 6154 100 N/A 11 ELAN C --- - --- - ISID-100
--------------------------------------------------------------------------------
2 out of 2 Total Num of i-sid endpoints displayed
ORIGIN Legend:
C: manually configured; D: discovered by FA or EPT
M: FA management; E: discovered by EAP; A: auto-sense
l: discover by local switch r: discover by remote VIST switch
Variable definitions
The following table defines parameters for the i-sid command to configure a Switched UNI.
|
Variable |
Value |
|---|---|
|
i-sid <1-16777215> |
Specifies the service interface identifier (I-SID). |
|
c-vid <1-4094> |
Specifies the customer VLAN ID. |
|
mlt <1–512> |
Specifies the MLT ID. |